Visit our website and learn more about AS/NZS standards. AS/NZS Regulatory compliance mark for electrical and electronic equipment – Specific requirements for particular regulatory requirements. Shown in the AS/NZS as the relevant standard that can be readily applied to the equipment type or;; Is accepted by the electrical safety regulator as a.

Author: Sagis Nabar
Country: Iraq
Language: English (Spanish)
Genre: Video
Published (Last): 23 November 2005
Pages: 306
PDF File Size: 8.14 Mb
ePub File Size: 15.44 Mb
ISBN: 786-2-17357-776-1
Downloads: 60525
Price: Free* [*Free Regsitration Required]
Uploader: Fejind

These regulations are undergoing a transition both in the means by which compliance is demonstrated, and in terms of harmonization between Australia and New Zealand. This part of the Standard deals with electromagnetic compatibility regulatory requirements in Australia and New Zealand.

Description You are required to comply with this standard if you intend to sell electrical articles. Consumer, Building nzzs Occupational Services Opens in new window.

New products manufactured in Australia xs imported into Queensland after the 30 Junemust comply with the requirements of In-Scope Level 3. It is understood that electrical regulators will continue to accept such marking nzzs a period, in parallel with the use of the RCM. At present DC isolators have not been gazetted as a prescribed article level 3. Main Content Clean Energy Ns. After 30 June all products must comply with the requirements of In-Scope level 3.

To date in Australia, marking of products with the number of the certificate of approval or certificate of suitability has been the usual means of indicating compliance. This issue affects the installation of household solar power systems in some states and we are conscious that it needs to be addressed 44172. The following table shows the basic requirements that are applicable. Clean Energy Council Insulation Accreditation.

We are very conscious of the urgency of this matter and have been in contact with safety regulators and state Ministers today to call for a transition period of at least six months.

  INTERVENTIVE INTERVIEWING PDF

Standards Catalogue

Home Products DC isolators update. Victoria Refer to the updated information above. There are also currently six 4147.2 for approval of DC isolators currently with ESV for assessment however, further technical documentation is required to be provided by the applicants in order to progress and finalise those approval applications.

In most states, it is an offence to supply level 3 or prescribed electrical equipment without being approved by a state electrical safety regulator or a JAS-ANZ accredited third party certifier. If you have any queries or require any further information, you can contact ESV’s Electrical Equipment Safety team on 03and select option 2. The Standard was prepared in response to a proposal from the Electrical Regulatory Authorities Coordinating Committee.

A code of practice is a set of rules which details how people in a certain industry should behave. Installer Sign In Search Search for.

Western Australia Refer to the updated information above.

Solar Accreditation – Update: Prescribed electrical equipment – DC isolators

Contact Email, Phone and Address Details for this service in simple two column table format, header then data. Electrical articles are electrical appliances or parts of electrical appliances. ESV will instead take an educational approach to the supply of unapproved DC isolators in the Victorian market provided, installers make every effort to source and install approved DC isolators and suppliers of DC isolators are in a genuine process of obtaining approval of their product.

To obtain a certificate, the products must comply with one of the following:. The closing date for comment on these draft standards is 7 September For electrical equipment that is required to be approved by regulators before being placed on the market declared articlesthere are specific regulatory requirements additional to the general requirements given in this Standard. By Admin July 16, Northern Territory Solar installations in NT are not affected at this stage.

AS/NZS – Standards Australia

It also sets out the regulatory compliance mark that should be used to mark this approval. To obtain a certificate, the products must comply with one of the following: This standard sets out the kind of electrical articles that require approval. There are a number of ways for suppliers to get their product certified. The objective of this Standard is to provide a set of outcomes-oriented criteria for the safety of electrical equipment, primarily for nzd by electrical regulators in relation to products for which regulatory approval before sale is not required non-declared articles.

  KORG AX3A PDF

Any new product types sourced by an importer would need to comply with level 3 requirements. Solar installations in NT are not affected at this stage. Solar 4417.2 in NSW are not affected at this stage. There is currently one product listed as being approved and one product listed with a voluntary certificate of suitability. 441.2 clarify, that is for existing stock.

Ensure your DC Isolators are AS/NZS 4417.2 compliant!

ESV has prioritised the processing of these applications. If DC isolators are manufactured or imported in SA prior to 30 Junethey may be sold in SA for a period of up to 6 months after this date i. Existing stock already in Australia aa 30th June is considered In-Scope level 1 and can continue being sold until 30 June provided the responsible supplier is registered. For the latest information for Tasmania download their fact sheet.

Energy Safe Victoria ESV expects suppliers who hold a voluntary certificate of suitability for their DC isolator to work with their certifier to obtain a valid certificate of approval. Please consult the Contact Officer for more information and to ascertain the level of 4147.2 that may be required. It is an offence under section 57 of the Act to supply Level 3 or prescribed electrical equipment that has not been approved by ESV, another electrical safety state regulator or JAS-ANZ accredited third party certifier.