ASTM International E Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference. ASTM E(). Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure. ASTM E is the standard test method for water penetration of exterior metal roof panels by uniform static air pressure difference. The ASTM E test.

Author: Tekora Zolonris
Country: Uganda
Language: English (Spanish)
Genre: Politics
Published (Last): 14 August 2014
Pages: 453
PDF File Size: 6.41 Mb
ePub File Size: 7.85 Mb
ISBN: 998-1-58377-665-1
Downloads: 11665
Price: Free* [*Free Regsitration Required]
Uploader: Samujinn

This process is repeated for a total of three cycles. In service, the performance also depends on the rigidity of supporting construction, roof slope, and on the resistance of components to deterioration by various causes: Practical considerations suggest that every combination of panel thickness, span, and design load need not be tested in order to substantiate product performance. SITC has utilized this test method to assist our clients with their quality assurance testing of metal panel roof systems.

Link to Active This link will always route to the current Active version of the standard. This test method shall not, by itself, be relied upon to form conclusions about overall water penetration through metal roofs. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. It is difficult to simulate the identical complex wetting conditions that can be encountered in service, including large wind-blown water drops, increasing water drop impact pressures with increasing wind velocity, and lateral or upward moving air and water.

  LAUTARO EPOPEYA DEL PUEBLO MAPUCHE PDF

After applying the preload there is a two minute recovery xstm. The test is conducted by attaching the chamber to the test specimen. A section of calibrated spray racks are set in place 12 inches above the specimen.

Prior to testing a positive static air pressure differential preload is applied. This test method is a specialized adaption of Test Method E Composite systems in which the source cannot be readily determined are outside the scope of this test method. It does not include leakage at openings or perimeter or any other details.

Although prescribed modifications are outside the scope of this test method, an experienced testing engineer is able to use the principles presented in this test method and generate significant data by isolating specific details and measuring leakage.

Then the specimen is preloaded with a negative static air pressure differential for a minimum of 10 seconds. Some designs are more sensitive than others to this upward moving water.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. These factors shall be fully considered prior to specifying the test pressure difference.

ASTM E1646

For specific hazard statements, see 7. In applying the results of tests by this method, note that the performance of a roof or its components, or both, may be a function of proper installation and adjustment.

  LULLY MISERERE PDF

The preload test pressure differences positive and negative are to be specified. This is a test procedure.

ASTM E – Farabaugh Engineering and Testing

These notes and footnotes shall not astn considered as requirements of the test method. The purpose of this test method is to conduct quality assurance water penetration testing of the roof including panel side laps and structural connections.

Historical Version s – view previous versions of standard. The positive test pressure shall e1466 greater than or equal to 15 pounds per square foot. For that reason the slope of the roof plays a significant importance. A roof contains many details. Pre-loading is a essential part of the testing procedure.

The slope of the roof is significant.

Read more about what our customers have to say The calibrated spray racks shall deliver water uniformly against the roof surface at a minimum rate of five gallons per square foot per hour. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.