Purchase your copy of IEC as a PDF download or hard copy directly from the official BSI Shop. All BSI British Standards. IEC Tests for electric cables under fire conditions – Circuit integrity – Part 1: Test method for fire with shock at a temperature of at least °C for. IEC / IEC Test method for fire with shock. Test set-up The cable is secured onto a positioning board and a flame is applied.

Author: Mubar Dalkis
Country: Senegal
Language: English (Spanish)
Genre: Finance
Published (Last): 10 June 2014
Pages: 142
PDF File Size: 13.12 Mb
ePub File Size: 10.37 Mb
ISBN: 884-5-62583-287-7
Downloads: 87123
Price: Free* [*Free Regsitration Required]
Uploader: Daizshura

Fire Resisting Characteristics of Electrical Cables Apparatus

The following test report forms are related: The test sample provides cable 6033-11 length at least mm. During the study, through all the cable wires is passed current with rated voltage and these cables are subjected to fire during min, where fire source is a gas burner set in conformity with standards, as well the echanical shock of the 5 minutes interval.

Result of the test is considered positive if at that time will not e considered a short circuit in the circuit being tested. Do you need a multi-user copy?

IEC | IEC Webstore

Our prices are in Swiss francs CHF. Bent wire on the U-shaped with a adius equal to the smallest permissible by the manufacturer, is mounted on a metal assay ladder. Result of the test is considered positive if at that time will not be considered a short circuit in the circuit being tested.

  AT SWIM-TWO-BIRDS FLANN ORIEN PDF

idc To better simulate the real fire conditions, with mechanical stresses due to the fall of materials and with the presence of water, the testing conditions have been modified by changing the duration, increasing the temperature of the flame and by adding mechanical stresses and water spray.

The significant technical changes with respect to the previous edition are as follows: Cables of smaller diameter are intended to be tested using the apparatus, procedure and requirements of IEC Result of the test is considered positive if at that time will 6031-1 be considered a short circuit in the circuit being researched.

In the 15 minutes period after the flame application, a maximum attenuation is also recorded.

Fire Testing

Annex A provides the method of verification of the burner and control system used for the test. Details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to metallic data and telecom cables and optical fibre cables are not given by IEC This second edition cancels and replaces the first edition published in Procedures and requirements — Electric Data Cables.

Procedures and requirements — Optic Fiber Cables. It constitutes a technical revision.

TC 20 – Electric cables rss. Related publications IEC Procedures and requirements — Cables of rated voltage up to and including 0.

IEC details a method to assess the circuit integrity of optical fiber cables. The time of the fire is minutes. The maximum change in attenuation a change from zero is recorded during the burner application period. Tests for electric cables for fire conditions and shock- Circuit integrity. It is divided in following parts that describe the test modes, the conditions, and the equipment to use. Preview Abstract IEC IEC applies to the cables with a diameter greater than 20mm, and introduces the standards nd procedures for testing of cables exposed ic fire and mechanical shock equipment according to Circuit insulation Integrity in accordance with IEC IEC specifies tests for electric cable for circuit integrity under fire conditions.

  ASTM F2170 PDF

Fire Testing Technology | Iec

Requirements are stated for an identification that may optionally be marked on the cable to signify compliance with this document. It is intended for use when testing cables of greater than 20 mm overall diameter.

During the test, to the wire cores of cable a 60331- of the nominal value is applied for telecommunication cables equal to Vthereby creating a closed electric circuit. The optical power meter is zeroed and the changes in attenuation during the minutes burner application period are monitored.

We accept all major credit cards American Express, Mastercard and VisaPayPal and bank transfers as form of payment. Procedures and requirements for fire with shock — Cables of rated voltage up to and including 0.

IEC ed 1.