AS NZS 3013 PDF

AS/NZS – Classification of the Fire and Mechanical Performance of Wiring System Elements This test is conducted in three parts: First Test. Download scientific diagram | Standard Time-Temperature Curve for AS/NZS from publication: CERAMIFYING INSULATION MATERIALS FOR FIRE. Austest Laboratories is pleased to announce further expansion of its capabilities to include mechanical testing of cables and wiring elements in.

Author: Nikotaxe Fejora
Country: Madagascar
Language: English (Spanish)
Genre: Technology
Published (Last): 8 September 2012
Pages: 350
PDF File Size: 13.10 Mb
ePub File Size: 19.32 Mb
ISBN: 807-4-19668-237-8
Downloads: 78230
Price: Free* [*Free Regsitration Required]
Uploader: Menris

Generally the level of mechanical performance 2nd numeral offered by polymeric insulated and sheathed cables is 2 moderate impact.

International Classification for Standards ICS is an international classification system for technical standards. Other people who purchased this product also bought Prysmian explains fire ratings for cable. A Title And here’s some amazing content.

Mechanical Test Method Impact ad Training Courses Voltimum webinars Voltimum e-Training. Webinar Presentation on Safely protecting the electric After a further 15 minutes the power is disconnected.

Sets out a classification scheme for wiring systems according to their resistance to the hazards of fire and mechanical damage.

The cable is deemed to have passed when it has been exposed to the specified level of impact energy without failure. To pass the requirements of this test, the cable must remain operational both during the 90 minute exposure and the 15 minute cooling period. Click Buy for Online Library subscription. This test is carried out in a 3m cubed enclosure where a cable sample is subjected to fire.

A wedge shaped indentor is forced against the cable specimen and loaded until it cuts through the insulation in order to determine the ability of the xs to withstand cutting action.

Cable Fire Ratings and What they Mean | Voltimum

In the main, these standards 301 referenced in relation to installations where international cable build standards such as IEC are being considered and assessment of their suitability to the building code of Australia lies with the specifying engineer.

  CLASSICAL ELECTROMAGNETISM BY JERROLD FRANKLIN PDF

May 03, Follow these links to find other Standards similar to the one you are viewing.

Within the context of these generic descriptions there is a myriad of performance tests in use around the world with which to qualify a cable to such requirements. The criteria of this test states that the weighted pH value should not be less than 4. The impactor which is set at the prescribed drop height, is dropped 3 times onto the specimen. A rating that defines the performance of a Wiring System.

After 90 minutes the gas is turned off. Fire-resistance tests of elemen AS Steel tubes and tubulars for ordinary service. It is designed to cover every economic sector and virtually every activity of the humankind where technical standards may be used.

The most common international standard relating to fire performance referenced 30013 specifying engineers is. Please Login or Register.

Cable Fire Ratings and What they Mean

Water Test Method After the cable specimen has passed the fire test, it is removed from the furnace and exposed to a water spray for 3 minutes. Please login or register. References This document may make references to other documents.

Level of protection against mechanical damage.

AS/NZS – Classification of the Fire and Mechanical Performance of Wiring Sy

International S tandards The most common international standard relating to fire performance referenced by specifying engineers is; IEC — Tests for electric cables under fire conditions — circuit integrity Part 21 – Procedures and requirements — cables of rated voltage up to and including 0. Ask an Expert Trade Talk. All referenced documents are displayed below. Intended for reference in other Standards which specify wiring systems with a degree of resistance to damage from fire or mechanical impact.

  DISTRIBUTED CHECKSUM CLEARINGHOUSE PDF

After removal of the flame, the cables are wiped clean and the charring should not have exceeded 2. The smoke emission and density are measured by alight beam emitted across the inside of the enclosure to a photocell, measuring the amount of luminous transmission received.

Type tests to verify the level of protection provided by a wiring system are given. The cable is deemed to have passed when the specimen has been exposed to the test for the appropriate minimum time requested by the submitter without a failure. Fire tests on building materials and structures – Methods for determination of the fire resistance of non-loadbearing elements of construction You may be interested in this related standard Methods for fire tests on building materials, components and structures – Simultaneous determination of ignitability, flame propagation, heat release and smoke release You may be interested in this related standard.

The world’s unique cable forum. This level of compliance can be met by most Australian fire rated power and control cables using standard constructional parameters from the relevant build standard s.

The letter “W” shall be applied as appropriate.

The cable specimen is conditioned, placed on the test apparatus anvil, and connected to the circuit integrity monitoring system. The cable is deemed to have passed when it has been exposed to the specified level of cutting force without failure. As tough as they get Nexans Olex Handbook.